Electrical Harmonics & Harmonic Filter FAQs

Electrical harmonics can affect power quality, energy efficiency and electrical equipment in commercial and industrial facilities. These unwanted electrical frequencies are commonly created by nonlinear loads such as HVAC systems, variable frequency drives (VFDs), LED lighting, computers, refrigeration equipment and other electronics.

These frequently asked questions explain what electrical harmonics are, what causes them, how they can affect a facility’s electrical system, and how the Tune Electrical Filter reduces unwanted harmonic distortion.

Tune Electrical Filter + Harmonics

Electrical harmonics are unwanted frequency components in an electrical system that occur at multiples of the fundamental power frequency (60 Hz in the United States). They are commonly generated by nonlinear electrical loads, including variable frequency drives (VFDs), LED lighting, computers, HVAC equipment and refrigeration systems.

Excessive harmonic distortion can reduce power quality, contribute to overheating in electrical components and increase electrical losses. Harmonic filtering technologies, including the Tune Electrical Filter, are designed to reduce unwanted harmonic distortion and support more efficient electrical system operation.

Electrical harmonics are primarily generated by nonlinear electrical loads—equipment that draws current in a non-sinusoidal pattern. Common sources include variable frequency drives (VFDs), LED lighting, computers, electronic power supplies, HVAC systems and commercial refrigeration equipment.

These devices can introduce harmonic distortion into a building's electrical system, potentially increasing electrical losses, generating excess heat and affecting power quality. The severity of these effects depends on the equipment, electrical system design and existing harmonic levels.

Electrical harmonics can increase energy losses by creating additional heating in transformers, wiring, motors and other electrical components. These losses occur when harmonic currents flow through a facility’s electrical distribution system.

The impact on total energy consumption depends on the severity of harmonic distortion, the equipment involved and the facility’s electrical configuration. Reducing excessive harmonics can help minimize these losses, improve power quality and support more efficient electrical system operation.

Businesses can reduce electrical harmonics by identifying sources of harmonic distortion and implementing appropriate power-quality solutions. Common approaches include passive harmonic filters, active harmonic filters, line reactors and equipment designed to minimize harmonic generation.

The Tune Electrical Filter is a passive filtering solution designed to reduce unwanted harmonic distortion in commercial electrical systems. Installed at electrical panels, it works to improve power quality, reduce associated electrical losses and support more efficient facility operations.

The most effective solution depends on the facility’s electrical configuration, equipment and measured harmonic levels.

The Tune Electrical Filter is a passive electrical filtering device designed to reduce unwanted harmonic distortion and improve power quality in commercial and industrial facilities.

Installed at a facility's electrical panels, the filter is designed to address unwanted harmonic frequencies generated by equipment such as HVAC systems, refrigeration, motors, lighting and electronics.

By reducing harmonic distortion, the Tune Electrical Filter can help minimize associated electrical losses and excess heat, supporting more efficient electrical system operation and potentially extending the service life of connected equipment.

Yes. The Tune Electrical Filter is designed to reduce unwanted electrical harmonics and associated energy losses, helping commercial and industrial facilities lower electricity consumption and operating costs.

Tune has documented energy savings across a variety of commercial applications, including restaurants, hotels, retail locations and industrial facilities. Actual savings vary based on electrical system characteristics, equipment, operating conditions and utility rates.

Tune uses measurement and verification (M&V) methods to evaluate energy performance and document results at individual facilities.

Electrical harmonics are common in commercial buildings that use equipment such as HVAC systems, variable frequency drives (VFDs), LED lighting, computers and refrigeration systems.

Potential warning signs of excessive harmonic distortion include overheating transformers, unusually warm electrical panels, nuisance circuit breaker trips and premature equipment failures. However, these symptoms can have other causes and do not necessarily indicate a harmonic problem.

The most reliable way to identify excessive harmonics is through a power-quality assessment using specialized electrical monitoring equipment. A qualified electrical professional can measure total harmonic distortion (THD), evaluate the results and determine whether corrective measures are appropriate.

The number of Tune Electrical Filters required depends on the facility's electrical configuration, the number and size of electrical panels, and the equipment connected to each panel.

Commercial buildings may require multiple filters to address harmonic distortion across different electrical circuits and distribution panels. Tune evaluates each facility's electrical system to determine the appropriate filter configuration and installation requirements.

A facility-specific assessment helps ensure the solution is properly sized and positioned for effective performance.

Yes. The Tune Electrical Filter has been evaluated through independent measurement and verification (M&V) studies conducted at commercial and industrial facilities.

These studies analyze electrical consumption before and after installation, accounting for relevant operating conditions and other variables that may influence energy usage. Tune has published documented results across multiple industries, including hospitality, restaurants, retail and manufacturing.

Independent evaluations help substantiate reported energy savings and provide facility owners with measurable performance data. Results vary by facility, and individual studies should be reviewed for their specific methodology and findings.

The Tune Electrical Filter is primarily designed to reduce unwanted electrical harmonics and improve power quality, rather than serve as a conventional power factor correction device.

Power factor correction typically addresses the relationship between real and apparent power, often by compensating for reactive power. Harmonic filtering addresses distortion in electrical waveforms caused by nonlinear loads.

Although harmonic distortion can affect overall power factor, harmonic filtering and conventional power factor correction serve different purposes. The appropriate solution depends on the facility's electrical characteristics and measured power-quality conditions.

Research and technical publications from the U.S. Department of Energy and IEEE document the effects of electrical harmonics on power quality and equipment performance.

These sources establish that nonlinear electrical loads can generate harmonic distortion, contributing to additional electrical losses, excess heat and equipment stress. They also describe how properly designed passive harmonic filters can reduce unwanted harmonic currents and improve power quality.

Reducing harmonic-related electrical losses may improve energy efficiency, although actual reductions in facility-wide electricity consumption depend on electrical system conditions and must be verified through measurement.

Supporting Research:

Tune Electrical Filter + Installation

A typical installation takes 15 to 30 minutes by a qualified electrician. Complete installation instructions are provided with each purchase. On request, technical assistance is available to support your successful installation via video or phone support.

A single Tune Electrical Filter properly installed should last between 8 to 10 years before any of the inductors’ windings open up and provide no inductance of the neutral.

None, it is an inductor connected in parallel to all of the neutral wire connections on the neutral bus bar.

Our goal with the Tune Electrical Filter is not to consume electricity. There is no app or other interface. You can measure the current on the lead wires using a hand-held meter to confirm the current is flowing through the filter to know that it's working. Measurement of the current flow through the device is recorded during installation.

The Tune Electrical Filter is installed in parallel on the neutral bus bar, working silently to reduce distortion and heat. If the filter quits working, the rest of the electricity in the panel continues as though the filter was never installed.

Tune Electrical Filter + Operation

The first Tune Electrical Filter devices were installed in 2012, and the USPTO issued the patent in August 2017. Inductors have been around for over 100 years but have never been applied in this manner.

We have installed thousands of Tune Electrical Filters in the USA. Resultsare available.

Electrical harmonics can contribute to energy losses by generating additional heat in transformers, wiring and other electrical components. These losses may increase a facility's electricity consumption, depending on its electrical system and equipment.

Modern utility meters are generally designed to measure electricity consumption accurately in the presence of harmonic distortion. However, excessive harmonics can contribute to inefficiencies that may affect overall energy costs.

The Tune Electrical Filter is designed to reduce unwanted harmonic distortion and associated electrical losses, helping commercial facilities improve power quality and potentially lower electricity consumption. Actual savings depend on facility conditions and should be verified through measurement and analysis.

The utility company charges you for the power you use based on the monthly readings of an electric meter that measures the current passing through the service entrance into your electrical service panel. The meter can either be a mechanical analog meter read monthly by a utility service person or a newer digital meter that may send information via internet or radio signals.

Total Harmonic Distortion (THD) is measured using a power quality analyzer or other specialized electrical monitoring equipment. These instruments measure harmonic distortion in voltage and current waveforms, helping identify potential power quality problems within a building's electrical system.

A qualified electrical professional can perform a power quality assessment at the main electrical service, distribution panels or individual equipment circuits. Measurements help determine the severity and sources of harmonic distortion and whether corrective measures, such as harmonic filtering, may be beneficial.

The Tune Electrical Filter is designed to reduce unwanted harmonic distortion. Comparing appropriate power quality measurements before and after installation can help evaluate its effectiveness in a specific facility.

Tune Electrical Filter + Safety

UL (Underwriter's Laboratory) certification was established in 2013 under file #E464646. UL has safety tested the product, and there have not been any incidents reported to us about the Tune Electrcial Filter as it relates to safety. Correct installation is always paramount to safety.

Tune Electrical Filter Warranty + Information

There is a Limited 10-year Manufacturer's Warranty for your Tune Electrical FIlter. You can view the terms of the warranty here.

We consider cost and efficiency when shipping orders of multiple devices, with an option to ship up to four per box.

Yes, a patent has been issued for the Tune Electrical Filter along with additional patents pending for expanded research. Tune was awarded its patent and registered with the U.S. Patent and Trademark Office (USPTO) in 2017. Ongoing research requires additional patent filings since the body of knowledge continues to expand.